Standards & load ratings
Bulk bag standards, load ratings and testing
Plain-English definitions of ISO 21898:2024, safe working load (SWL), 5:1, 6:1 and 8:1 test ratios, CE/UKCA and LOLER boundaries, and how to read a sewn-in bulk bag label.

Standards by cargo
Which standard applies to my bag?
Your site risk assessment and product classification decide which framework applies. Load ratings and approvals always come from the individual bag’s own test report, data sheet and sewn-in label.
01 / DRY NON-HAZARDOUS
Standard dry non-hazardous goods
Covered by ISO 21898:2024 (flexible intermediate bulk containers for non-dangerous solid materials), defining SWL, cyclic top-lift test ratios (5:1, 6:1 and 8:1), duty classes and sewn-in label markings. Bulk bags
02 / FOOD & FEED
Direct food or animal feed ingredients
Food-contact materials fall under Great Britain Assimilated Regulations 1935/2004, 10/2011 (plastics) and 2023/2006 (GMP) in 100% virgin plastic; feed sites work to UFAS (Universal Feed Assurance Scheme), FEMAS (Feed Materials Assurance Scheme) and GB Feed Hygiene rules. Food-contact and approval paperwork
03 / STATIC CONTROL
Flammable dusts or static-sensitive powders
Electrostatic classifications under BS EN IEC 61340-4-4 (supporting DSEAR / ATEX site risk assessments): Type A (no static protection) and static-protective Type B, Type C (conductive, earthed) and Type D.
04 / DANGEROUS GOODS
Solid dangerous goods (UN / ADR)
ADR (the European agreement on carrying dangerous goods by road) requires applicable design-type tests (such as top-lift, tear, stacking where designed to stack, drop, topple and righting) and a permanent UN mark: 13H1 (uncoated, no liner), 13H2 (coated, no liner), 13H3 (uncoated with liner), 13H4 (coated with liner) and 13H5 (plastic film). Chemicals and manufacturing
05 / AGRICULTURAL FILM
Agricultural silage wrap film
Roll width, length, thickness, tack and UV protection are confirmed from the maker’s data sheet for the specific film quoted. Bale wrap film
Load ratings & test ratios
SWL, geometric volume and 5:1, 6:1 and 8:1 test ratios
Dimensions give geometric volume (m³), describing internal space alone. Safe working load (SWL, in kg) is the maximum net load a full bag is designed to carry when lifted, and two bags of identical size can carry different load ratings.
SINGLE-TRIP
5:1 safety factor
Single-trip duty class under ISO 21898:2024, designed for one filling.
- Top-lift test Cyclic test finishing at 5× SWL
- Use class Single-trip only
STANDARD REUSABLE
6:1 safety factor
Standard-duty reusable class for limited fillings and discharges. 6:1 does not mean six uses and does not increase SWL.
- Top-lift test Cyclic test finishing at 6× SWL
- Use class Limited reuse per maker rules
HEAVY-DUTY REUSABLE
8:1 safety factor
Heavy-duty reusable class under ISO 21898:2024 for intensive reuse subject to the maker’s specification.
- Top-lift test Cyclic test finishing at 8× SWL
- Use class Intensive reuse per maker spec
DANGEROUS GOODS
UN 6× test vs ISO 6:1
Under ADR 6.5.6.5.2, UN flexible IBCs are tested to 6× maximum permissible gross mass (bag, liner and contents combined).
- Distinction Does not make a UN bag an ISO 21898 6:1 reusable bag
- Verification Always check the sewn-in label and data sheet

Sewn-in labels
How to read a sewn-in bulk bag label
When asking us to quote a match for the bag you use now, photograph the sewn-in label clearly so these details are readable.
- 01 SWL (kg) The stated safe working load in kilograms. Never infer load capacity from bag dimensions alone.
- 02 Safety factor & duty class The printed test ratio (5:1 single-trip, 6:1 standard-duty reusable or 8:1 heavy-duty reusable) alongside the maker’s handling pictograms.
- 03 Standard & stacking limit The standard reference (such as ISO 21898) and stacking limit or “do not stack” pictogram (on a UN mark, a stacking test figure of 0 means not approved for stacking).
- 04 Maker & manufacture date Manufacturer name or code, design reference, lot number and manufacture date (MM YY on UN marks) used for traceability and stock rotation.
- 05 UN or static mark Any UN dangerous goods mark (13H1 to 13H5, packing group X/Y/Z, stacking load and max gross mass) or static classification (Type B, C or D under IEC 61340-4-4).
- 06 Check the data sheet too Fabric weight (g/m²), coating, spout diameters, UV stabilisation test regime and liner gauge rarely appear on sewn-in labels. Send your existing data sheet or a sample if you have one.
UK audit boundaries
Regulatory boundaries: CE/UKCA, LOLER, ADR and UV
Clear answers to the regulatory questions UK quality and safety teams ask most often.
01 / MACHINERY
Why bulk bags do not carry CE or UKCA marks
Under the UK Supply of Machinery (Safety) Regulations 2008, FIBCs are classified as packaging containers rather than lifting accessories, so standard bulk bags do not carry CE or UKCA marks. Spreader beams, lifting frames, forklift hook attachments and separate slings are lifting accessories and do require UKCA/CE marking.
02 / INSPECTION
LOLER 1998 vs PUWER
Mechanical lifting equipment and accessories sit under LOLER (HSE L113) for statutory thorough examination. As packaging, the suitability and pre-use condition of an FIBC sit within the site’s PUWER assessment, CPA TCIG TIN 026 guidance and the maker’s stated duty class.
03 / UN 13H
UN flexible IBCs vs rigid IBC 5-year rule
The statutory 5-year limit in ADR 4.1.1.15 and 2.5/5-year periodic inspections in ADR 6.5.4.4 apply to rigid and composite plastic IBCs (such as 11H/21H/31H/31HA1), not flexible IBCs (13H1 to 13H5). Flexible UN bags must still be in sound condition, free from UV or moisture degradation, with stock rotated using their MM YY manufacture date and maker storage guidance.
04 / LINERS
Bag and liner compatibility
Under BS EN IEC 61340-4-4, liners are classified separately (L1/L2/L3) alongside the bag: fitting a standard insulating PE liner inside a Type B, C or D bag can invalidate electrostatic protection. Under ADR Chapter 6.5, changing the liner in a 13H3 or 13H4 bag voids its tested design approval.
05 / OUTDOOR STORAGE
UV stabilisation testing
ISO 21898:2024 baseline UV testing uses accelerated laboratory exposure (retaining at least 50% tensile strength after cyclic exposure), which does not equate to a guaranteed number of outdoor calendar months. Flag outdoor yard storage at quote stage so UV requirements are checked on the maker’s data sheet.
Specification match
Checking a replacement bag beyond dimensions
Five physical checks that stop a drop-in replacement jamming a filling line or racking.
01 / SHAPE
Body construction and bulge
Standard tubular, U-panel and 4-panel bags bulge wider when filled, whereas baffle (Q-bag) designs hold a square footprint for pallets, racking and curtain-siders.
02 / FABRIC
Fabric weight, coating and seams
Uncoated fabric breathes; coated fabric and sift-proof seams help retain fine powders. Confirm whether a fitted liner is used instead.
03 / LIFTING
Loop style and free height
Cross-corner loops, side-seam corner loops and tunnel-lift sleeves affect how bags engage filling frames and forklift tines.
04 / SPOUTS
Spout geometry and closures
Check filling and discharge spout diameters, length and tie or iris closures against your existing hoppers and discharge rigs.
05 / TRIALS
Pre-order sample trial-fill
Ask for a physical sample before committing to volume so your operators can verify loop engagement, spout clamping, filled stability and label legibility on your line.
Quality & compliance
More compliance guidance

Quality and compliance
Documents, SAQ quick facts and how we handle compliance.

Plastic Packaging Tax and EPR
Recycled content, liner rules and the April 2027 changes.

Food-contact, feed and approval paperwork
Declarations, feed rules and clean-handling options.
Written trade quotes
Send us your bag label or specification
Request a quote and attach a photo of your label, dimensions, top/base style and any liner.
We reply within one working day.
Or call our sales team
FAQs
Does a 6:1 safety factor mean a bulk bag can be used six times?
No. A 6:1 ratio describes the design’s final top-lift test load (six times SWL), not a count of refills. Whether a specific bag is classed for reuse, and under what conditions, comes only from its label, maker instructions and your site’s qualified assessment.
Does a larger bulk bag automatically carry a heavier load?
No. Internal volume in cubic metres comes from dimensions alone, whereas safe working load (SWL) depends on fabric weight, loop stitching, base construction and design testing. Always check the stated SWL on the bag’s label and data sheet.
What do UN codes 13H1 to 13H4 mean on a bulk bag?
Under ADR Chapter 6.5, 13H1 is an uncoated woven plastic FIBC with no liner, 13H2 is coated with no liner, 13H3 is uncoated with a liner, and 13H4 is coated with a liner (13H5 is a plastic film FIBC). The mark applies only to that specific tested design.
Why don’t bulk bags carry a CE or UKCA mark?
Under the UK Supply of Machinery (Safety) Regulations 2008, FIBCs are classified as packaging containers rather than lifting accessories, so CE or UKCA marking does not apply to them. Mechanical lifting frames, spreader beams and separate slings do require UKCA/CE marking and LOLER inspection.